X-ICP detects fine-grained LiDAR localizability from scan-to-map correspondences and constrains point-to-plane ICP updates along degenerate directions; tested on a legged robot in a mine, a construction site and a park.

技術屬性

欄位內容為文獻擷取紀錄的原文用語(英文),以原文為據;「未查證」表示本研究尚未讀到該資訊,不代表該方法不具備此能力。

X-ICP 的技術屬性
感測輸入3D LiDAR (Velodyne VLP-16; Ouster OS0-128)、IMU、leg joint encoders (leg odometry prior)
原文測試平台legged、simulation
狀態估計scan-to-map point-to-plane ICP with localizability-driven constrained optimization (Lagrange multipliers) that fixes or limits updates along degenerate directions (abstract, Sec. VI)
資料關聯scan-to-map correspondences analysed against principal optimization directions for fine-grained localizability (abstract)
時間表示discrete poses
去畸變point cloud motion compensation done at the LiDAR driver level with the leg-odometry pose estimates in the transformation tree; the pose prior is used to transform and undistort the input cloud
迴圈閉合none
全域最佳化none
地圖表示point cloud map in a libpointmatcher-based registration framework (Sec. VII-A)
先驗資訊leg odometry prior (IMU + joint encoders) as initial guess (Sec. VII-A)
可輸出幾何pose updates; resulting point cloud maps compared with TLS reference maps (Sec. VII)
計算需求mapping pipeline runs at 5 Hz (Sec. IV); single-threaded scan-to-map registration on the Rumlang data takes 32.19 (10.7) ms with X-ICP on an Intel i7-9750H laptop, stated to be equivalent to the robot computer, and 12.65 (3.51) ms on an Intel i9-13900K, vs 20.05 (2.21) ms and 11.1 (1.45) ms for the baseline without localizability awareness, whose statistics cover only the first 150 s of the run (Table V); localizability overhead per ICP iteration shown only as a plot (Fig. 20)

使用設備

原文使用的感測器、運算硬體與載具(equipment)。型號保留原文寫法,連結到設備頁中同一型號的歸併名稱;角色依原文用途分為方法輸入、資料集感測器、執行運算平台、參考或真值量測(reference or ground truth)與比較對象設備。

原文使用的設備
類別型號(原文寫法)角色資料集原文規格出處
LiDARVelodyne VLP-16方法輸入未標示16-beam (sparse) LiDAR on ANYmal-C; used in all field experiments(Tuna et al., 2024, Sec. VII-A, VII-G3)
LiDAROuster OS0-128方法輸入Seemuhle mine repeat runmuch higher point density and larger FoV than VLP-16; 128-beam (dense) LiDAR(Tuna et al., 2024, Sec. VII-D2, VII-G3)
地面雷射掃描儀(TLS)Leica RTC 360歸入:Leica RTC360參考或真值量測Seemuhle mine and Opfikon City Park ground-truth maps原文未報告(Tuna et al., 2024, Sec. VII-D, VII-F, Fig. 6-c)
慣性量測單元(IMU)inertial measurement unit (IMU)方法輸入未標示原文未報告(Tuna et al., 2024, Sec. VII-A)
輪式或腿式里程計joint encoders方法輸入未標示used with the IMU by ANYmal's leg odometry module (ref. [69]) to provide the registration prior(Tuna et al., 2024, Sec. VII-A)
載具平台ANYmal-C方法輸入未標示legged robot(Tuna et al., 2024, Sec. VII-A, Fig. 6)
運算硬體Intel i7-9750H執行運算平台未標示laptop CPU equivalent to the one on the robot; single-threaded timing(Tuna et al., 2024, Sec. VII-A, Table V)
運算硬體Intel i9-13900K執行運算平台未標示desktop-class CPU; single-threaded timing(Tuna et al., 2024, Sec. VII-G3, Table V)

作者報告的優勢與限制

優勢

限制

營建工程相關證據

作者實測:瑞士 Rumlang 大型營建工地 153 m 路線(開放平面、原地旋轉),以地圖一致性定性比較;Seemuhle 地下礦坑隧道段以 TLS 參考地圖量化。屬單一研究、單一工地,不可推廣為一般工地性能。

原文驗證環境:模擬、施工中工地、地下或隧道、獨立參考量測

報告的性能數據

以下是原文作者報告的性能數值(author-reported results),不是本研究重新量測的結果。每張圖只並列同一個比較組(comparison group,同一張表、同一組實驗設定)內的方法;不同比較組之間的數值不可直接比較,也不構成排名。

本方法共出現在 12 個比較組,合計 65 筆紀錄。以下列出本方法紀錄最多的 4 組,其餘 8 組列在最後,並連到性能比較頁。

Tuna et al., 2024 · Table III 本方法 18 筆

資料集與序列Seemuhle underground mine (authors' data) · VLP-16 run; first 15 m alignment

表格設定(擷取紀錄原文,這些數值分屬表中不同部分):(Tuna et al., 2024, Table III)

  • Ablation, Seemuhle VLP-16 APE (same protocol as Table I); Xs-ICP drops the partial-localizability category and categorizes only in the first ICP iteration
  • Same setting as other Table III rows

APE Translation mu(sigma) [m],Seemuhle underground mine (authors' data) · VLP-16 run; first 15 m alignment

只並列這張表在相同設定下報告的方法;以「本方法:」開頭者為本頁方法。失敗、未執行與未報告以標記呈現,不是 0。

按 Tab 進入圖表後,用上下方向鍵逐一瀏覽各類別,Esc 關閉提示框;也可開啟表格檢視閱讀全部數值。

這些是 Tuna et al., 2024 在此表設定下報告的數值(author-reported results),只能在同一個比較組內對照,不代表方法在其他資料或設定下的表現。

統計量:平均值(mean);對齊方式:原文未報告;單位:m;場景:underground mine tunnel

資料來源作者報告值(Tuna et al., 2024, Table III)

數值與出處
方法(原文寫法)報告值出處
X-ICP (Proposed)本方法原文提出2.05 m(Tuna et al., 2024, Table III)
Xs-ICP (Proposed)本方法原文提出2.29 m(Tuna et al., 2024, Table III)

Tuna et al., 2024 · Table I 本方法 9 筆

資料集與序列Seemuhle underground mine (authors' data) · VLP-16 run; first 15 m alignment

表格設定(擷取紀錄原文,這些數值分屬表中不同部分):(Tuna et al., 2024, Table I)

  • Seemuhle underground mine, ANYmal with VLP-16, 521.8 m; APE via EVO against Leica RTC 360 ground truth, mu (sigma); 'first 15 m' = trajectory aligned on the first 15 m (about 200 poses), 'origin' = aligned at the first pose; plus last-position error
  • Same setting as other Table I rows

APE Translation mu(sigma) [m],Seemuhle underground mine (authors' data) · VLP-16 run; first 15 m alignment

只並列這張表在相同設定下報告的方法;以「本方法:」開頭者為本頁方法。失敗、未執行與未報告以標記呈現,不是 0。

按 Tab 進入圖表後,用上下方向鍵逐一瀏覽各類別,Esc 關閉提示框;也可開啟表格檢視閱讀全部數值。

這些是 Tuna et al., 2024 在此表設定下報告的數值(author-reported results),只能在同一個比較組內對照,不代表方法在其他資料或設定下的表現。

統計量:平均值(mean);對齊方式:原文未報告;單位:m;場景:underground mine tunnel

資料來源作者報告值(Tuna et al., 2024, Table I)

數值與出處
方法(原文寫法)報告值出處
X-ICP (Proposed)本方法原文提出2.05 m(Tuna et al., 2024, Table I)
Zhang et al. [12]3.36 m(Tuna et al., 2024, Table I)
Hinduja et al. [17]5.79 m(Tuna et al., 2024, Table I)

Tuna et al., 2024 · Table IV 本方法 8 筆

資料集與序列Seemuhle underground mine (authors' data) · VLP-16 run

表格設定(擷取紀錄原文,這些數值分屬表中不同部分):(Tuna et al., 2024, Table IV)

  • Ablation, RPE per 10 m traversed distance, Seemuhle VLP-16, mu (sigma)
  • Same setting as other Table IV rows

RPE Translation mu(sigma) [m] per 10 m,Seemuhle underground mine (authors' data) · VLP-16 run

只並列這張表在相同設定下報告的方法;以「本方法:」開頭者為本頁方法。失敗、未執行與未報告以標記呈現,不是 0。

按 Tab 進入圖表後,用上下方向鍵逐一瀏覽各類別,Esc 關閉提示框;也可開啟表格檢視閱讀全部數值。

這些是 Tuna et al., 2024 在此表設定下報告的數值(author-reported results),只能在同一個比較組內對照,不代表方法在其他資料或設定下的表現。

統計量:平均值(mean);對齊方式:未對齊;單位:m;場景:underground mine tunnel

資料來源作者報告值(Tuna et al., 2024, Table IV)

數值與出處
方法(原文寫法)報告值出處
X-ICP (Proposed)本方法原文提出0.17 m(Tuna et al., 2024, Table IV)
Xs-ICP (Proposed)本方法原文提出0.19 m(Tuna et al., 2024, Table IV)

Tuna et al., 2024 · Table V 本方法 8 筆

資料集與序列Rumlang construction site (authors' data) · 153 m run

表格設定(擷取紀錄原文,這些數值分屬表中不同部分):(Tuna et al., 2024, Table V)

  • Scan-to-map registration time per scan on the Rumlang construction-site data, single-threaded, mu (sigma); baseline statistics computed only until 150 s into the run to avoid the degenerate part
  • Same setting as other Table V rows

scan-to-map registration time mu (sigma) [ms],Rumlang construction site (authors' data) · 153 m run

只並列這張表在相同設定下報告的方法;以「本方法:」開頭者為本頁方法。失敗、未執行與未報告以標記呈現,不是 0。

按 Tab 進入圖表後,用上下方向鍵逐一瀏覽各類別,Esc 關閉提示框;也可開啟表格檢視閱讀全部數值。

這些是 Tuna et al., 2024 在此表設定下報告的數值(author-reported results),只能在同一個比較組內對照,不代表方法在其他資料或設定下的表現。

統計量:平均值(mean);對齊方式:未對齊;單位:ms;場景:construction site, open planar area

資料來源作者報告值(Tuna et al., 2024, Table V)

數值與出處
方法(原文寫法)報告值出處
X-ICP(Intel i9-13900K, single thread)本方法原文提出12.65 ms(Tuna et al., 2024, Table V)
X-ICP(Intel i7-9750H, single thread)本方法原文提出32.19 ms(Tuna et al., 2024, Table V)
Xs-ICP(Intel i9-13900K, single thread)本方法原文提出11.14 ms(Tuna et al., 2024, Table V)
Xs-ICP(Intel i7-9750H, single thread)本方法原文提出29.42 ms(Tuna et al., 2024, Table V)

其他比較組

列出其餘 8 個比較組

來源

  • Tuna et al., 2024

    Turcan Tuna, Julian Nubert, Yoshua Nava, Shehryar Khattak, Marco Hutter(2024)X-ICP: Localizability-Aware LiDAR Registration for Robust Localization in Extreme EnvironmentsIEEE Transactions on Robotics, 40:452-471

    同儕審查已出版已讀全文近十年

回到方法圖鑑